Exor ePALM10 Product Manual Download Page 1

 

Tech-note

 

tn202-2.doc - 10.01.2012  
ePALM10 Product Manual 

 

 

ePALM10 Product Manual 

The ePALM10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The 
rugged polyamide enclosure offers a high level of shock and environmental resistance making the 
ePALM the ideal choice for use in the factory floor. 
 

Contents 

1

 

Highlights .......................................................................................................................... 3

 

2

 

Technical data ................................................................................................................... 4

 

3

 

Operation .......................................................................................................................... 6

 

3.1

 

Enabling Switches ................................................................................................ 6

 

3.2

 

Indicators and Keypad ......................................................................................... 6

 

3.3

 

Battery Replacement............................................................................................ 7

 

3.4

 

Power Supply and Grounding .............................................................................. 8

 

3.5

 

Applicable Regulations ........................................................................................ 9

 

3.6

 

Installation Environment ....................................................................................... 9

 

3.7

 

Cleaning Faceplates .......................................................................................... 10

 

3.8

 

Getting Started ................................................................................................... 10

 

3.8.1

 

Serial Communication ........................................................................................ 10

 

3.8.2

 

Ethernet Communication ................................................................................... 10

 

3.9

 

Troubleshooting ................................................................................................. 10

 

4

 

Connections .................................................................................................................... 11

 

4.1

 

Serial Communication - Types –0061 and –0062 .............................................. 11

 

4.1.1

 

Using Optional Fieldbus Modules ...................................................................... 14

 

4.1.2

 

Connecting the ePALM to the Simatic S7 MPI network ..................................... 15

 

4.2

 

Ethernet Communication - Type –0066 and –0068 ........................................... 16

 

4.3

 

Profibus DP Communication - Type –0067 and –0069 ..................................... 19

 

4.3.1

 

Termination switch ............................................................................................. 21

 

4.3.2

 

Programming connector ..................................................................................... 22

 

5

 

Accessories ..................................................................................................................... 23

 

Summary of Contents for ePALM10

Page 1: ...tors and Keypad 6 3 3 Battery Replacement 7 3 4 Power Supply and Grounding 8 3 5 Applicable Regulations 9 3 6 Installation Environment 9 3 7 Cleaning Faceplates 10 3 8 Getting Started 10 3 8 1 Serial...

Page 2: ...ional S p A Verona Italy Subject to change without notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the i...

Page 3: ...rial devices Transflective LCD display ensures readability under the most critical light conditions Display dynamic data in numerical text bargraph and graphic image formats Recipe data storage Recipe...

Page 4: ...ickness of cable 11 mm diameter Environmental Conditions Operating temperature 0 to 50 C EN 60068 2 14 Storage temperature 20 to 70 C EN 60068 2 14 Operating and storage humidity 5 85 RH non condensin...

Page 5: ...M10 0061 Serial 5m Yes Yes two normal ePALM10 0062 Serial 10m Yes Yes two normal ePALM10 3P61 Serial 5m Yes Yes one 3 position ePALM10 3P62 Serial 10m Yes Yes one 3 position ePALM10 0066 Ethernet 5m S...

Page 6: ...lly open contacts are wired directly to the controller The 3 positions switch must be operated as described in the table Position Button status Contacts Function 1 Released Open Not enabled 2 Pressed...

Page 7: ...being performed The RDA mapping of LED indicators is shown in the table below RDA Bit LED on Key RDA Bit LED on Key L1 F1 L17 L2 F2 L18 1 L3 F3 L19 2 L4 F4 L20 3 L5 F5 L21 4 L6 F6 L22 5 L7 F7 L23 6 L...

Page 8: ...Battery replacement 3 4 Power Supply and Grounding The unit must always be grounded to protection earth PE Grounding helps limit the effects of noise due to electromagnetic interference on the contro...

Page 9: ...Two hand controls 9 4 Control function in case of failure Do not use operator interface to directly command motors valves or other actuators not equipped with safeguards and potentially harmful to pe...

Page 10: ...e panel and the personal computer are speed 9600 38400 baud parity None stop bit 1 The Designer software defaults to the correct parameters 3 8 2 Ethernet Communication When applicable Designer can us...

Page 11: ...e following groups of signals are available in the cable PC Printer Port PLC Port Aux Port Power Emergency Stop button two NC contacts Two 2 positions enabling switches NO contacts In all the most com...

Page 12: ...al assignment in CN1 refers to the corresponding assignment in the Aux Port of the standard panel mount version of the product This correspondence will be useful to adapt the normal cable drawings for...

Page 13: ...p 2 NC Orange 1 17 Note the wiring of the Emergency Stop button is to be considered a SELV circuit and it is intended only for connection to low voltage circuits below 48 VDC The standard cable layout...

Page 14: ...6 Wiring layout The figure shows the standard assembly of the communication cable Please note that the ferrite toroid is required for proper operation and should not be removed To program the ePALM10...

Page 15: ...e Aux Port CN1 must be manually changed to connect the appropriate signals Fieldbus topologies do not allow long 5 10 meters drop segments the wiring must include incoming and outgoing segments for al...

Page 16: ...switch two independent NO contacts Please note that this product does not include connections for the following standard ports PC Printer Port PLC Port Aux Port Note this version of the product does...

Page 17: ...ctional are not wired to the connection cable and are not available for applications The information on CN4 is provided for reference only The signals wired to the cable are listed in the table below...

Page 18: ...ch note tn202 2 doc 10 01 2012 ePALM10 Product Manual 18 BLUE SHIELD TRACE N C BLACK RED YELLOW GREEN BROWN ORANGE BLUE BLACK CYAN GREEN WHITE GREEN ORANGE WHITE ORANGE CYAN BLACK Figure 9 Wiring layo...

Page 19: ...itch two independent NO contacts Please note that this product does not include connections for the following standard ports PLC Port Aux Port Note this version of the product has a special connector...

Page 20: ...o low voltage circuits below 48 VDC The wires in the cable are color coded according to the table below Signal Color S mm 2 AWG approx Power 24 VDC Red 0 75 21 Common Black 0 75 21 Aux Port Profibus A...

Page 21: ...Wiring layout 4 3 1 Termination switch The ePALM has been designed only for connection at one of the two ends of the Profibus DP network Figure 12 Network topology Profibus DP requires termination of...

Page 22: ...nector On the back of the ePALM a RS 232 serial port is available for programming the device the drawing below shows the position and the pin out of the connector 1 7 Figure 14 Programming connector P...

Page 23: ...accessories are currently available for the ePALM10 products hooks for hanging the handheld device Hooks are available in two versions AHOOK01 without magnet and AHOOK02 with a magnet The hook with th...

Reviews: