background image

Installation and operation manual

Job name: _________________________________
Installer:  __________________________________
Installation date:  ___________________________

Product information  

Chapters 1 + 2

Mechanical installation  

Chapter 3

Electrical installation  

Chapter 4

Start up and configuration  

Chapter 5

Maintenance and troubleshooting  

Chapter 6

READ AND SAVE THESE INSTRUCTIONS!

GSV 009-016 grease fan

Manufacturer contact information:

exodraft a/s • Tel: +45 7010 2234

[email protected] • www.exodraft.com

3001361 GSV009-016 Grease fan 20210824 - international

Summary of Contents for GSV 009

Page 1: ...information Chapters 1 2 Mechanical installation Chapter 3 Electrical installation Chapter 4 Start up and configuration Chapter 5 Maintenance and troubleshooting Chapter 6 READ AND SAVE THESE INSTRUC...

Page 2: ...intenance and troubleshooting 6 1 Care and cleaning 12 6 2 Chimney cleaning intervals 12 6 3 Creosote formation and need for removal 12 6 4 Inspection schedule 12 6 5 Chimney fires and what to do abou...

Page 3: ...building inhabitants about possible danger 3 Inspect your cooking appliance and chimney sur roundings for possible fire If in doubt alert your fire department 4 Do not continue to use your appliance u...

Page 4: ...is made of stainless steel and is completely in balance The motor is a direct drive variable speed class H insulated high temperature motor It has perma nently lubricated and sealed ball bearings and...

Page 5: ...DE the junction box Please do not discard 1 4 Warranty 2 Year Factory Warranty We promise the original user that we will replace or repair as we may elect any part or parts of the new GSV Chimney Fan...

Page 6: ...oltage VAC 1 x 120 RPM 1600 1600 1600 1580 Amps A 0 5 1 4 2 9 5 3 Motor power kW 0 025 0 10 0 16 0 35 Weight lbs 28 46 60 86 kgs 12 18 26 35 Dimensions A in 9 85 11 03 13 20 14 97 mm 250 280 335 380 B...

Page 7: ...3 2 Installation on steel duct y Insert the steel chimney adapter into the chimney where the long collar engagement ensures safe anchoring see Fig 2 If necessary the adapter can be secured by means of...

Page 8: ...cated on one of the sides Never on the upside or downside y Seal around the fan base to make sure it is watertight and no water can slip in between the fan and the adapter Do not block the 4 drain hol...

Page 9: ...re supplied with the system must be replaced use similar wire of the same temperature rating Otherwise insulation may melt or degrade exposing bare wire 4 2 Wiring diagram The connection diagram below...

Page 10: ...a couple of minutes y Spillage can be detected by introducing smoke into the flue products ahead of the draft hood or by observing if the flame of a match goes out when it is held at the edge of the...

Page 11: ...ions follow normal instructions on burning a fire in a fireplace or stove After the fire catches on after 3 5 minutes reduce the speed of the grease fan to a level where it safely removes the flue gas...

Page 12: ...flue lining When ignited this creosote makes an extremely hot fire Creosote causes many problems Some are visible while others are not It can make trouble if y It runs down outside the pipe to damage...

Page 13: ...ay up the chimney and may cause chimney fan damage The creosote may be burning inside the chimney If you can see flames coming out of the top you are either over firing or there is a chimney fire If t...

Page 14: ...rt 08 Bird screen 09 Top plate 10 Axial vane 12 Locking hinge 2 13 Cooling vane 14 Screw SS 16 Washer SS 17 Screw SS 4 21 Motor housing insulation 22 Screw SS 2 23 Washer SS 24 Screw SS 29 Screw SS 31...

Page 15: ...he power OFF immediately Open the fan and check if the mo tor shaft is straight If not contact ENERVEX tel 800 255 2923 Turn off the power and remove the foreign article clean the fan The fan is noisy...

Page 16: ...Notes www exodraft com...