background image

Your energy. 

Optimized.

Chimney Fan

Draftbooster

UK

 

 |   Read and save these instructions!

Summary of Contents for DB7B01

Page 1: ...Your energy Optimized Chimney Fan Draftbooster UK Read and save these instructions ...

Page 2: ......

Page 3: ...distance 12 Assembly parts 13 Assembling the bottom flange 13 Installing the bottom flange and wire on the Draftbooster 14 Installation onto a brick chimney 15 Installation onto a steel chimney 17 Electrical wiring 19 Startup and configuration 20 System testing 20 Operating fireplace or stove 20 Maintenance and troubleshooting 21 Care and cleaning 21 Troubleshooting 22 UK Conformity Assessed 23 De...

Page 4: ...r waste and disposed of according to national legislation to protect the environment and personnel that may come into contact with waste How to use this manual This manual has been prepared based on the specific product and contains relevant technical information and installations guides Accessories and spare parts are not covered by this manual Please refer to the individual manuals of these compo...

Page 5: ...rks a dangerous situation that in the worst case scenario can cause serious personal injury or significant damage to the product Electricity hazard High Voltage Marks a situation in which caution is advised due to the risk of high voltage electric shock which can cause serious personal injury or significant damage to the product Connect an earth terminal to the ground Failure to observe instructions...

Page 6: ...ney fires Prior to servicing the product disconnect the power and ensure that it cannot accidentally be reconnected Exodraft always recommends the use of a smoke alarm when a solid fuel fireplace is installed If the Exodraft fan system has been designed for solid fuel multi fuel installations please ensure that the design meets the requirements of BS EN15287 1 If this cannot be achie ved a smoke ala...

Page 7: ...control Warranty All Exodraft products are covered by a 2 year guarantee as per European consumer rights legislation For some countries an extended period of guarantee may apply depending on either national legislation or other clearly stipulated conditions Customer complaints must be handled by a specialised dealer or who lesaler preferably where the Exodraft product has been bought originally An...

Page 8: ...mply turn on the Draftbooster again leaving it active as long as necessary The remote control socket is designed for indoor use only Check that the voltage indicated on the rating plate corresponds with that of the local network before connecting the socket to the mains power supply Long range transmitting distance up to 30m in free air The remote controlled socket unit has been pre programmed and...

Page 9: ... Shaded pole class H Voltage 1V x 230 AC Rev m 2 000 Current 0 27 Amp Power consumption 0 036 kW IP 24D Data Motor specifications Weight 3 2 Kg A x B x C mm 266 x 230 x 140 Impedance protected Yes Max temperature during operation 250 C Max temperature at standstill 250 C Technical data ...

Page 10: ...nstruction and components 1 Switch 2 Cable screw joint 3 Motor 4 Net outlet 5 Vane 6 Lid 7 Locking mechanism of lid 8 Inlet air 9 Drainholes 10 wireless outlet with remote control and battery 11 Assemble kit 1 2 9 8 5 6 4 3 7 11 10 ...

Page 11: ...d of support to carry the weight of the chimney fan System type Fireplaces and wood stoves used in private dwellings normally operate in a relatively stable environment where no major pressure fluctuations occur However to secure an optimal use of the Exodraft system speed adjustments and adjustment of air intakes are required depending on the weather outside and on the stage of the firing process...

Page 12: ...an The Draftbooster can be mounted horizontally or vertically Be aware of national law and building regulations Minimum distance The minimum distance to flammable materials must be at least 500 mm national legislation must be observed Min distance according to national legislation ...

Page 13: ...UK 13 3112038_Draftbooster_UK Assembly parts 1 4 x 2 4 x 3 4 x 4 4 x 5 1 x 6 2 x 7 1 x 8 1 x 9 1 x 10 4 x 11 1 x 12 1 x Assembling the bottom flange 10 4 x 12 1 x 11 1 x 1 4 x 2 4 x ...

Page 14: ...14 UK Your energy Optimized Installing the bottom flange and wire on the Draftbooster 3 4 x 9 6 ...

Page 15: ...er of your chimney and fix the legs in this position The legs must be fastened permanently in the adequate position with the 4 self tapping screws This example shows the setting for an inside chimney diameter of ø150 mm 4 4 4 4 150 180 200 220 3 The Draftbooster can now be lowered into place with the flange legs into the chimney IMPORTANT Do not screw or bolt the brackets into the flue pipe ...

Page 16: ...he wire lock Tighten the safety wire slightly and then tighten the wire lock so that the chimney fan is secured Before taking the fan into operation please make sure that the nuts in the location brackets have been tightened the safety wire has been fastened to the Draftbooster and chimney the safety wire and the wire lock have been tightened the Draftbooster is securely closed ...

Page 17: ...he steel chimney 2 Adjust the flange legs to fitting the inner diameter of your chimney and fix the legs in this position The legs must be fastened permanently in the adequate position with the 4 self tapping screws This example shows the setting for an inside chimney diameter of ø150 mm 4 4 4 4 150 180 200 220 3 The Draftbooster can now be lowered into place with the flange legs into the chimney ...

Page 18: ...on and tighten the wire lock The wire must be tight to secure that the Draftbooster stays on the chimney but not so tight that it makes the Draftbooster tilt 7 4 Before taking the fan into operation please make sure that the nuts in the location brackets have been tightened the safety wire has been fastened to the Draftbooster and chimney the safety wire and the wire lock have been tightened the D...

Page 19: ...t used the plug from the Draftbooster can be pluged directly to a wall outlet Possibly with an on off switch The remote controlled socket unit have been pre programmed and can be used immediately CAUTION The remote control socket is designed for indoor use only DANGER If the need arises to replace the original Draftbooster cord use a cord of the same type Otherwise the insulation can melt or erode...

Page 20: ...control has a boost function please activate this Light the fire and make sure there is no spillage of flue gases from the fireplace opening When the fire has caught on reduce the speed of the chimney fan to a point where it still removes the flue gases safely but without quenching the flames Remember this setting on the fan speed control as this will be the ideal operating position speed of the c...

Page 21: ...leaned by a trained professional chimney sweep Note Soot and other deposits must be removed from the rotor blades and from the bottom of the motor housing The run capacitor is considered a wear part and will need to be replaced depending on usage Cleaning procedure Step Action 1 Switch off the power to the fan and make sure the fan doesn t rotate 2 Open the lid of the fan 3 Using a scraper or brus...

Page 22: ... the axial vane impeller stick Check capacitor and replace if necessary Clean the fan The Draftbooster seems to work fine but there is not enough draught The fan may be undersized The capacitor may be worn out The flue is damaged blocked Replace with a larger fan Check capacitor and replace if necessary Check the flue chimney sweep The Draftbooster vibrates The motor shaft may be bent The Draftboo...

Page 23: ...anufactured in conformity with the provisions of the following regulations The Supply of Machinery Safety Regulations 2008 Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regulations 2016 Langeskov 01 11 2022 Managing Director Anders Haugaard UK Conformity Assessed DB7B01 DB7B02 DB7S01 DB7S02 ...

Page 24: ...ation överensstämmer med följande standard er Jota tämä selvitys koskee on seuraavien standardien mukainen Sem eru meðtalin i staðfestingu Pessari eru i fullu samræmi við eftirtalda staðla Sono stati fabbricati in conformità con le norme degli standard seguenti EN 60335 1 EN 60335 2 80 DS EN ISO 12100 2011 I h t bestemmelser i direktiv In accordance with Entsprechen gemäß den Bestimmungen der folg...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...xodraft no www exodraft no UK Exodraft Ltd 24 Janes Meadow Tarleton GB Preston PR4 6ND Tel 44 0 1494 465 166 Fax 44 0 1494 465 163 info exodraft co uk www exodraft co uk DE Exodraft a s Niederlassung Deutschland Soonwaldstr 6 DE 55569 Monzingen Tel 49 0 6751 855 599 0 Fax 49 0 6751 855 599 9 info exodraft de www exodraft de FR Exodraft sas 78 rue Paul Jozon FR 77300 Fontainebleau Tel 33 0 6 3852 3...