14 Troubleshooting
Solving Common Problems
Before calling EXFO’s technical support, please read the following
common problems that can occur and their respective solution.
Problem
Possible Cause
Solution
Optical Laser LED is off and the
connector is not generating the
signal.
The
Laser On
option is disabled.
Ensure that the
Laser
button is
enabled (On).
There is a configuration mismatch
between the inserted transceiver
and the rate selected for the test
case.
Ensure that the transceiver is
supporting the rate used for the
test case.
The transceiver is not compatible
with the module.
Ensure to use a compatible
transceiver. Refer to
Unable to edit the
Operator Name
in Generate Report
page.
This is the expected behavior when
the
EXFO Connect Server
check
box is selected in
EXFO Connect
Client
, since the
Operator Name
is
selected from the EXFO Connect
operator name list.
To edit the
Operator Name
:
- Clear the
EXFO Connect Server
check box from
EXFO Connect
Client
.
-
Close and restart the module
application.
Transceiver System (TA4) not
detected.
TA4 is not inserted properly.
Remove the TA4 from the 88460
module, and carefully follow the
insertion procedure described on
page 15.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...