12 Power Failure Recovery
The automatic power failure recovery is used to select, configure, and
restart
1
the test that was running before the power failure; a test that was
not running will be selected and configured but not started. To provide this
level of protection, the configuration of the current test is automatically
saved; the logger, injections, and configuration are periodically saved.
A power failure occurs when the AC power is down (LTB-8 and FTB) while
the unit’s battery (FTB) has not sufficient power to keep the unit running.
Pressing the platform power button for 5 seconds performs a power down
reset and is also considered as a power failure condition. The Windows
Hibernate
or
Sleep
mode is also considered as a power failure condition.
When the power returns, the automatic power failure recovery restarts the
platform, the module application, then selects, configures, and starts the
test if it was running before the power failure.
Note:
If the automatic power failure recovery is not used, restarting the module
after a power failure automatically selects, configures, and starts the test if
it was running before the power failure.
1. Not applicable for iSAM, EtherSAM, RFC 2544, RFC 6349, TCP Throughput, and Cable Test applications; these tests
must be started manually.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...