Test Results
Power Blazer
581
Summary (S-OAM and MPLS-TP OAM)
Loopback / Test / Frame Delay / Frame Loss /
Synthetic Loss
Note:
Either
Loopback
,
Test
,
Frame Delay
,
Frame Loss
, or
Synthetic Loss
(available with Ethernet OAM) statistics are displayed according with the
selected test function (refer to
Status
displays the status of the test function.
For
Loopback
,
Frame Delay
,
Frame Loss
, and
Synthetic Loss
(available with Ethernet OAM) functions:
For
Test
function:
Status
Description
Idle
No Results (function did not run yet).
In Progress
Test is in progress. Frames are being transmitted and monitored.
Completed
Test is completed:
The test with continuous transmission is manually stopped and replies have been received
or timed out.
The test with continuous transmission is automatically stopped by a test timer and replies
have been received or timed out.
All frames of the test with non-continuous transmission have been transmitted and replies
have been received or timed out.
Aborted
Test is aborted. The test with non-continuous transmission is stopped before all the frames
are transmitted.
Status
Description
Idle
No Results (function did not run yet).
In Progress
Test is in progress. RX TST frames are being monitored.
Completed
Test is completed. The test is stopped or function is disabled after being In Progress state.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...