Test Results
550
88000 Series
Summary (Cable Test)
Operation
Note:
The following results are only reported when the classification succeeded.
Unloaded Voltage (V)
indicates the measured voltage when no load is
applied. A value less then 5 is reported as
<5.0
and a value greater
than 59 is reported as
>59.0
.
Loaded Voltage (V)
indicates the measured voltage by applying a load
corresponding to the configured power class. A value less then 5 is
reported as
<5.0
and a value greater than 59 is reported as
>59.0
. The
Pass/Fail verdict is also displayed when enabled.
Current (mA)
indicates the current which is calculated based on the
measured
Loaded Voltage
and the applied load.
Power (W)
indicates the power in watt which is calculated based on
the measured
Loaded Voltage
and
Current
.