Test Results
520
88000 Series
SDT (Multi-Channel OTN)
Total (ms)
indicates the total duration of all measured disruption
times.
Count
indicates the number of disruption events detected since the
beginning of the test.
PASS FAIL
, available when pass/fail verdict is enabled, indicates the
SDT pass/fail verdict.
Time Mode
selects the format used to display the disruption time.
Relative
displays SDT events based on the time elapsed since the
beginning of the test.
Absolute
(default) displays SDT events based on date and time.
Units
selects the unit used to display SDT statistics:
μ
s, ms (default), s,
or min.
Time Stamp
displays the time or date/time for each SDT channel; this
apply to
Longest
and
Last
disruption time statistics. Choices are
None
(default),
Time
, and
Date/Time
. An extra line is added for each
channel to display the time, and two lines to display the time and date.
Note:
When a disruption event is equal to or longer than the test period which is
fixed to 5 minutes, then the measured disruption time is equal to the test
period.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...