Test Results
452
88000 Series
Alarms/Errors Overview
RS-FEC
Note:
Available with 25/100GE rate when RS-FEC is enabled.
Alarms
FEC-LOA
(FEC-Loss Of Alignment)
RX
: Deskew process is not complete meaning that not all lanes are
synchronized (Alignment Marker locked) and aligned.
FEC-LOAML
(FEC-Loss Of Alignment Marker Lock)
RX
: The location of the alignment marker payload sequence for a given
lane on the PMA service interface is not detected.
Error
Inv-CW-Marker
(Invalid Codeword Marker)
RX
: The received Codeword marker is invalid.
FEC-COR-CW
(FEC Correctable Codeword)
RX
: FEC Codeword that contains errors and were corrected.
FEC-UNCOR-CW
(FEC Uncorrectable Codeword)
RX
: FEC Codeword that contains errors and were not corrected.
Pre-FEC-SYMB
(Pre-FEC Symbol)
RX:
For 25GE, FEC symbol errors are corrected and counted once for
each 10-bit symbol.
RX
: For 100GE, FEC symbol errors are corrected and counted once for
each 10-bit symbol.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...