Test Results
Power Blazer
431
Alarms/Errors Overview
FSF
(Forward Signal Fail)
RX
: The FTFL byte 0 is “00000001”.
TX
: Generates a “00000001” pattern in the FTFL Byte 0 continuously.
LCK
(Lock)
RX
: STAT information in the PM byte 3, bits 6 to 8 is “101” for at least 3
consecutive frames.
TX
: Generates a repeating "01010101" pattern in the entire ODUk signal,
excluding the frame alignment overhead (FA OH) and OTUk overhead
(OTUk OH).
LOFLOM
(Loss of Frame Loss Of Multiframe) is only available for
mapped ODU client signal (designated as LO in the standard).
RX
: OOF is present for at least 3 ms.
TX
: Generates error continuously in FAS and MFAS of a multiplexed
test case.
OCI
(Open Connection Indication)
RX
: STAT information in the PM byte 3, bits 6 to 8 is “110” for at least 3
consecutive frames.
TX
: Generates a repeating "01100110" pattern in the entire ODUk signal,
excluding the frame alignment overhead (FA OH) and OTUk overhead
(OTUk OH).
TIM
(Trace Identification Mismatch)
RX
: The received SAPI and/or DAPI do not math the expected SAPI
and/or DAPI. This alarm is only available when the SAPI ODU-TIM
and/or DAPI ODU-TIM check boxes are selected from
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...