Test Results
410
88000 Series
Alarms/Errors Overview
Ethernet - PCS Lanes
Note:
Available with parallel interfaces only: 40/100/200/400 Gbit/s Ethernet and
OTN with 40/100 GbE Ethernet client. Available under the
PCS
sub tab for
Through Mode test providing alarms/errors for both ports.
Skew Alarm Threshold (bits)
, available with Ethernet test application,
allows setting the threshold value that will be used to declare a skew
alarm. Not available at 100G when the RS-FEC check box is selected.
Default
restore the default skew alarm threshold value.
Alarms
Note:
For
LOA
and
Inv. Mapping
alarms see
LOBL
(Loss of Block Lock)
RX
: In lock mode, 65 invalid sync fields (00 or 11) within a 1024 sync
window are received. A PCS Lane Lock alarm is cleared when
receiving 64 consecutive valid 66b sync field (01 or 10) in a row.
Available with 40/100G.
LOAML
(Loss of Alignment Marker Lock)
RX
: In lock mode, four consecutive marker values are received that do
not match the alignment marker that the lane is currently locked to.
The LOAML alarm is cleared when the PCS Lane is declared Lock and
two valid alignment markers 16384 blocks (66b) apart are received.
Rate
Range
Default Value
400G
200G
0 to 10550
4781
100G
0 to 2047
928
40G
0 to 4095
1856
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...