![EXFO Power Blazer 88200NGE User Manual Download Page 406](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938406.webp)
Test Results
396
88000 Series
Alarms/Errors Overview
BER
Alarms
No Traffic
(Available with EtherBERT or OTN BERT with EoOTN client)
RX
:
Ethernet: No pattern traffic has been received in the last second.
Fibre Channel: No traffic is being transmitted when Login Management
fails; a pop up displays
No Data is being transmitted on Port(s)
<port number>. The Login process has failed
.
Pattern Loss
RX
:
Ethernet: More than 20 percent of bit errors are received or the
reference sequence can be unambiguously identified as out of phase.
However, for OTU4 -
4 Unframed Physical Lanes
and 100GE -
4 Unframed CAUI-4
, bit error rate is greater than 2.5x10
-3
.
Fibre Channel: bit error is detected on four consecutive words.
Client Frequency
(Available for ODUflex with Pattern client)
RX
: The received client signal rate doesn’t meet the nominal bit rate
configured ± 100 ppm (refer to
Nominal Bit Rate
Errors
Bit Error
RX
: There are logic errors in the bit stream (i.e., zeros that should be
ones and vice versa). Only the count and rate values are reported for
unframed test 40GE/OTU3 and up.
Pattern Error
RX
: Indicates a block mismatch. Available with
Seed A
or
Seed B
pattern.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...