![EXFO Power Blazer 88200NGE User Manual Download Page 314](http://html1.mh-extra.com/html/exfo/power-blazer-88200nge/power-blazer-88200nge_user-manual_2449938314.webp)
Test Setup - Test Configurator, Timer, and System
304
88000 Series
RFC 6349
Discover Remote
button, available with
Dual Test Set
, allows
discovering remote modules supporting
Dual Test Set
. For more
details, refer to
Direction
allows the selection of the traffic direction:
Local to Remote
,
Remote to Local
, and
Bidirectional
(default).
Remote IP Address
, available with
EXFO|Worx Interop
, is either the
remote IP address of the verifier or the WAN IP address when the
verifier is behind a NAT router.
TCP Port
is the port used by the server located at the remote side:
1
to
65535
(excluding
62819
that is used for DTS connection), default is
50201
. The port forwarding rule for the defined TCP port must be
created on the NAT router when the remote is behind a NAT.
Parameters
Multiple Connections
check box when selected (default) indicates
that the applicable TCP Throughput phases are performed with
multiple connections; otherwise TCP Throughput phases are
performed within a single connection. For 40/100GE rate, this check
box is selected and the
Window Size Target per Connection
can be
used to set the target window.
Window Size Target per Connection
, available for 40/100GE rate,
selects the target window per connection: 1 MiB, 4 MiB, 8 MiB, 16 MiB
(default), and 32 MiB.
CIR
The Local-to-Remote CIR and Remote-to-Local CIR represent the
Committed Information Rate of the Ethernet Service under test:
1.0 Mbit/s
to Line Rate. The CIR is not used to actually transmit frames
at this rate but to calculate a Bandwidth Delay Product (BDP) which in
turn is used to set the Max Window Size of the TCP connections.
Rate Unit
determines the unit used to display the rate values:
Mbit/s
(default) or
Gbit/s
.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...