Test Setup - Test Configurator, Timer, and System
208
88000 Series
Fibre Channel
Login
After a link is established, it is possible to login to the Fibre Channel
Network to send and receive data between a local and remote fibre
channel port.
Enable
check box when selected (default) allows pressing the
Login
button to start the login process.
Advertised BB_Credit
is the number of frame buffers the local port has
available to receive frames from the remote port:
1
to
65535
(default is
10
).
Advertised BB_Credit
is advertised to the remote port through the
Login
process. Changing the
Advertised BB_Credit
requires to
manually re-send a login using the
Login
button.
Login/Re-Login
button allows the initiation of the Login process with
the selected
Advertised BB_Credit
. Available when the
Login
-
Enable
check box is selected. The
Login
button initiates a log-in when
not logged-in while the
Re-Login
re-initiates a log-in after changing the
BB_Credit
and/or
WWN
when already logged-in. The capability to login
is available only with Framed Layer 2 (FC-2) when a successful link has
been established. There are two Login processes supported by Fibre
Channel:
Port Login
(PLOGI) and
Fabric Login
(FLOGI).
It is possible to skip the
Login
procedure and use the
BB_Credit
value.
This is called
Implicit Login
and is only applicable for
Point-to-Point
topology. For
Point-to-Point
topology using implicit login, you must
manually configure the
Available
BB_Credit
value for the remote port.
Discovered Topology
indicates the discovered topology.
Fabric
: Ports are interconnected to a fabric switching network.
A
Fabric
and
Port
login are required, and the
BB_Credit
value is set
based on the buffer capacity of the fabric switch.
Point To Point
: Direct link between two ports.
Summary of Contents for Power Blazer 88200NGE
Page 1: ...www EXFO com User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE...
Page 14: ......
Page 20: ......
Page 64: ...Test Setup Test Applications 54 88000 Series OTN BERT...
Page 71: ...Test Setup Test Applications Power Blazer 61 SONET SDH BERT For SDH BERT...
Page 76: ...Test Setup Test Applications 66 88000 Series SONET SDH DSn PDH BERT For SDH...
Page 620: ......
Page 726: ......
Page 752: ......
Page 756: ......
Page 768: ......
Page 886: ...0 5 1 5 48 5 0 176 W d y K y K D...