Test Results
532
88000 Series
Traffic - Flow Control
Pause Injection
Note:
Pause injection is only available for Traffic Gen & Mon test application.
Packet Pause Time
: Enter the pause time value to be transmitted in
Quanta
or
Microsecond
(default is
100
Quanta).
Note:
When entering a value in
μ
s it will be rounded to the closest multiple of
0.0512 for 10 Gbit/s, 5.12
μ
s for 100 Mbit/s, 0.512
μ
s for 1000 Mbit/s, 0.0512
μ
s
for 10 Mbit/s, 0.0128 for 40 Gbit/s, and 0.00512 for 100 Gbit/s.
Inject
button allows generating the defined packet pause time.
Destination MAC Address
check box, when selected (cleared by
default), enables and allows setting the destination MAC address. The
default destination MAC address is the control protocol multicast
address:
01:80:C2:00:00:01
.
Interface
Range
Quanta
μ
s
10 Mbit/s
0
to
65535
0
to
3355392
100 Mbit/s
0
to
65535
0
to
335539.2
1000 Mbit/s
0
to
65535
0
to
33553.92
10 Gbit/s
0
to
65535
0
to
3355.392
40 Gbit/s
0
to
65535
0
to
838.848
100 Gbit/s
0
to
65535
0
to
335.5392
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......