Test Results
Power Blazer
517
Summary (TCP Throughput)
TCP Throughput
TCP Connection Status
indicates the actual TCP connection status.
Transmitted Frames
indicates the total of frames transmitted by the
local unit excluding the re-transmitted frames.
Re-transmitted Frames
indicates the total of frames that have been
re-transmitted by the local unit.
Efficiency (%)
indicates the percentage of bytes that were not
retransmitted.
Window Size Unit
allows selecting the unit used for
Window Size
:
Bytes
,
KBytes
, or
MBytes
(default).
Throughput Threshold
allows setting the pass/fail verdict threshold
value:
0
to
100 %
(default). This setting is available when the
Throughput Pass/Fail Verdict
check box is selected (refer to
Throughput
meter displays the last second TCP Throughput
measurement.
Test Status
Description
“--”
The test is not running or results are not available.
In Progress
The TCP initialization algorithm is in progress.
Waiting
Indicates on the remote unit that the test is started but the
TCP initialization algorithm is not initiated by the local unit.
Established
The TCP session has been successfully established between the
local and remote units.
Closed
The session is closed. Either no TCP initialization algorithm has
been received, the remote unit has received and completed the
request to close the TCP session, or no data has been received
at the remote unit for 30 seconds.
Closing
The TCP protocol is closing down the connection.
Remote IP not found
The local unit didn’t received an answer to the ARP request sent
to the IP address of the remote unit.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......