Test Results
Power Blazer
421
FTFL/PT and PT
FTFL/PT and PT
For OTN BERT and OTN-SONET/SDH BERT: From the
Test
menu tap
Results
, and the
FTFL/PT
tab.
For Multi-Channel OTN: From the
Test
menu, tap
Results
, and the
PT
tab.
Channel
Available with Multi-Channel OTN, allows the selection of the channel
number.
ODUx/ODUk Buttons
Tap on an
ODUx/ODUk
button to select the multiplexed level. For
Multi-Channel, the ODUk level displayed will be the one corresponding to
the selected channel.
FTFL
Indicates the Forward and Backward ODU Fault Type Fault Location. Not
available with Multi-Channel OTN.
Fault Indication
and
Code
displays the FTFL fault indicator message
and its code in hexadecimal format (byte 0 for forward, byte 128 for
backward).
Fault Indication
Code
No fault
00 (default)
Signal fail
01
Signal Degrade
02
Reserved
03