Test Setup - Test Configurator, Timer, and System
210
88000 Series
MAC/IP/UDP
MAC
Source MAC Address
indicates the default and unique Media Access
Control (MAC) address given to the Ethernet port; editable when using
Provider Encapsulation
.
Destination MAC Address
: Enter the destination MAC address for the
stream. The default setting is the source MAC address. The destination
MAC Address field is not accessible when the
Resolve MAC Address
check box is selected.
Resolve MAC Address
check box, when selected (default), sends a
request to the network to retrieve the MAC address corresponding to
the selected destination IP address. This setting is coupled with the
Resolve MAC Address
is not available when the
Network Layer
is set to
None
(refer to
OAM Quick Ping
button automatically starts the quick Ping utility for
the stream destination MAC address and provides either a successful
or failed result. The quick Ping uses 3 attempts, a delay of 1 second,
and a Timeout of 5 seconds.
EtherType
is set to the following values by default and is configurable
from
0x0000
to
0xFFFF
when the
Network Layer
is set to
None
:
0x0000
when
Network Layer
is set to
None
0x0800
for IPv4
0x86DD
for IPv6
0x8847
for MPLS
0x88B7
when
Network Layer
is set to
None
with EtherBERT test.
0x8902
for S-OAM (available with EtherSAM)
OUI
, available when the frame format
802.3 SNAP
is selected, allows
the selection of the Organizationally Unique Identifier (OUI):
RFC1042
(0x000000) - (default)
User Defined
, available when
Network Layer
is set to
None
, allows
entering the
OUI
value:
0x000000
(default) to
0xFFFFFF
.
Summary of Contents for Power Blazer 88000 Series
Page 1: ...User Guide 88000 Series Power Blazer HIGH SPEED MULTISERVICE TEST MODULE ...
Page 12: ......
Page 16: ......
Page 22: ......
Page 28: ......
Page 38: ......
Page 58: ...Test Setup Test Applications 46 88000 Series OTN BERT ...
Page 64: ...Test Setup Test Applications 52 88000 Series SONET SDH BERT For SDH BERT ...
Page 69: ...Test Setup Test Applications Power Blazer 57 SONET SDH DSn PDH BERT For SDH ...
Page 550: ......
Page 670: ......
Page 674: ......
Page 686: ......