Copper Auto Tests
MaxTester Copper Test
235
User Auto Test
Multimeter 2 Result
The
Multimeter 2 Result
page displays the following
results:
Resistive Balance
-
R-Leg
,
T-Leg
,
Loop
resistance, and pass/fail status and values in
Ω
and %.
Isolation
- pass/fail status,
Resistance
and a
Soak
Counter(s)
for each wire
Pair
. If your unit has the
HIVOLT (high voltage) software option
configured, it enables
Isolation Resistance
testing up to 500 V. Default is inherited from
Multimeter Isolation
test.
Capacitance/Opens
and
Length
for each wire
Pair
.
Noise Result1
The
Noise Result
page displays the following results
and pass/fail status:
VF Noise
measures voice frequency noise in the
line.
Power Influence
measures the effects that 50 Hz
and 60 Hz powerline (AC Mains) interference has
on the circuit under test.
VF Impulse Noise
-
High
,
Mid
,
Low
counts,
respective detection levels, and
Elapsed Time
.
Here the pass/fail status is for the
Mid
level only.
WB Impulse Noise
- impulse
Count
,
Detection Level
, and
Elapsed
Time
.