RFL
218
MAX-610
RFL Cable Setup
RFL Cable Setup
The
Cable Setup
page allows you to set cable
parameters for an RFL test. Settings are shared by
both
Single Pair
and
Separate Good Pair
tests.
Changes done in
Cable Setup
for one test are
reflected in the other.
No. of Cable Sections
allows you to set the
number of consecutive cable sections, to a
maximum of 5. If unknown, set the number to 1.
Cable Type
allows you to select a cable entry
(with its associated parameters) from the current
Cable Book
, to use for testing. The selection is not
saved when leaving the test. The current Cable Book entry is shown by
default.
Resistance
specifies a value for the resistance constant of the cable in
each section.
Section Length
allows you to specify the cable length of each section.
If the cable length is unknown, specify 0 and the RFL test will measure
the length.
Load Coil
allows you to set the detection of the presence of load coils
to either
Yes
or
No
.
Cable Temperature
allows you to change the temperature of the cable
under test in either degree
C
or
F
.