Test Functions
MaxTester
377
Spare Bits
Spare Bits
Note:
Spare Bits
are not available when the framing is set to
Unframed
.
From the
Test
menu, tap
Functions
, tap the
Spare Bits
tab.
TX
Tap a spare bits field to set its value.
Note:
All spare bits are reserved for national use and should be set to 1 when not
used.
E4
G.751 Bit 14, 15, 16
: Choices are
000
to
111
(default).
E3
G.751 Bit 12
: Choices are
0
and
1
(default).
E1
S
i0
is located in the bit 1 of the frame containing the frame
alignment signal (FAS). Choices are
0
and
1
(default).
S
i1
is located in the bit 1 of the frame not containing the frame
alignment signal (FAS). Choices are
0
and
1
(default).
S
a4
to
S
a8
are located in bit 4 to 8 of frame number 1, 3, 5, and 7 of
sub-multiframe 1 and 2. Choices are
0
and
1
(default) or
0000
to
1111
(default) depending on the selected framing.
TS16 Frame 0 Bit 5, 7, 8
are located in bit 5, 7, and 8 from Timeslot
16 of frame 0 of a E1 signal. Choices are
000
to
111
(default).
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...