Test Results
MaxTester
247
Alarms/Errors Overview
VT/TU
Alarms
AIS-V
(Alarm Indication Signal - VT) - SONET
TU-AIS
(Tributary Unit - Alarm Indication Signal) - SDH
RX
: V1 and V2 bytes for the VT/TU path contain an all-ones pattern in
three (SONET) / five (SDH) consecutive superframes.
TX
: Generates an all-ones pattern for the V1 and V2 bytes of the VT/TU
path and payload.
LOP-V
(Loss Of Pointer - VT) - SONET
TU-LOP
(Tributary Unit - Loss Of Pointer) - SDH
RX
: A valid pointer is not found in N consecutive superframes (where
8
N
10), or if N consecutive NDFs (“1001” pattern).
TX
: Generates a non-valid pointer.
RDI-V
(Remote Defect Indication - VT) - SONET
LP-RDI
(Tributary Unit - Remote Defect Indication) - SDH
RX
: Bit 8 of the V5 byte contains “1” in five consecutive VT/TU
superframes while bits 6 and 7 of the Z7 (SONET) / K4 (SDH) byte
contain the “00” or “11” pattern.
TX
: Generates “1” for the bit 8 of the V5 byte and a “00” pattern for bits
6 and 7 of the Z7 (SONET) / K4 (SDH) byte.
RFI-V
(Remote Failure Indication - VT) - SONET
LP-RFI
(LOP - Remote Failure Indication) - SDH, available with VC-11
only.
RX
: Bit 4 of the V5 byte contains “1” in five consecutive superframes.
TX
: Generates “1” for the bit 4 of the V5 byte.
Summary of Contents for MAX-800 Series
Page 1: ...www EXFO com User Guide MAX 800 Series MaxTester Application ETHERNET AND TRANSPORT TESTER...
Page 16: ......
Page 18: ......
Page 26: ......
Page 43: ...Test Setup Test Applications MaxTester 35 SONET SDH BERT For SDH BERT...
Page 48: ...Test Setup Test Applications 40 MAX 800 Series SONET SDH DSn PDH BERT For SDH...
Page 62: ......
Page 208: ......
Page 414: ......
Page 426: ......
Page 473: ...Glossary MaxTester 465 SONET DSn SDH PDH The GUI Grid indicates the TUG 2 x and TUG 3 x values...
Page 476: ......
Page 494: ...0 5 1 5 48 5 0 176 W d y K y K D...