![EXFO MAX-635G User Manual Download Page 176](http://html.mh-extra.com/html/exfo/max-635g/max-635g_user-manual_2450059176.webp)
SmartR™ Features
166
MAX-635G
FaultMapper
FaultMapper
The
FaultMapper
is a graphical snapshot of the pair to locate and identify
line faults. It combines and analyzes the results of several different tests
including capacitance, resistance, TDR, and RFL, to draw a diagram of the
pair depicting common faults.
FaultMapper
does not find all faults but
rather many common faults, and can identify more than one at a time. This
test is useful in locating bridged taps, shorts, grounds, and opens but only
one bridged tap at a time. (To look for more bridged taps, clear the first
bridged tap and run the test again). The
TDR
function key is available for
your reference, although FaultMapper is not solely a TDR and performs
some signal analysis.
FaultMapper
can identify and/or locate the following:
Shorts
Grounds (strap required to determine distance)
Opens
Detect load coils
Bridged tap
The
FaultMapper
page displays the following parameters:
Current Test
displays the test being measured.
Far End Strap
allows you to select option
Yes
or
No
for use of a strap.
A strap, while not required, enables
FaultMapper
to calculate distance to a ground/earth fault. The
test will use some RFL routines here, and you do
not have to exit to run RFL. (
RFL
is located on the
Copper Main
menu.)
Cable Setup
button opens a new page that allows
you to set the
Cable Parameters
for the
Current
Test
.
Summary of Contents for MAX-635G
Page 1: ...User Guide Copper and G fast VDSL2 ADSL2 Multi play Test Set MAX 635G www EXFO com ...
Page 10: ......
Page 26: ......
Page 162: ......
Page 218: ......
Page 270: ...TDR 260 MAX 635G Continuous Examples of Common Faults Short Fault ...
Page 271: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 261 Continuous Open ...
Page 272: ...TDR 262 MAX 635G Continuous Bridged Tap ...
Page 273: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 263 Continuous Splice Joint ...
Page 274: ...TDR 264 MAX 635G Continuous Peak Function ...
Page 275: ...TDR Copper and G fast VDSL2 ADSL2 Multi play Test Set 265 Continuous Dual Trace View ...
Page 276: ...TDR 266 MAX 635G Continuous Load Coil ...
Page 290: ......
Page 336: ......
Page 414: ......
Page 424: ......
Page 432: ......
Page 438: ......
Page 444: ......