Port Tabs
Ethernet and Fibre Channel Application
159
Advanced Auto-Neg. RX
Advanced Auto-Neg. RX
Note:
Advanced auto-negotiation is not available with the optical 100 Mbps and
10 Gig-E interfaces.
Press
TEST
,
Port1/2
, and
Advanced Auto-Neg RX
.
Status
Link
: A green Link LED indicates that there is a link at the input port of
the corresponding Ethernet interface. A red LED indicates that there is
no link at the input port of the corresponding Ethernet interface.
Auto-Negotiation
: Indicates the auto-negotiation status. Possible
values are:
Negotiating
: indicates that the auto-negotiation process is running and
not completed yet.
Completed
: indicates that the auto-negotiation process has completed
successfully.
Parallel Detect Fail
: indicates that auto-negotiation has failed through
the parallel detection process while negotiating in 10/100Base-T.
Remote Fault
: Indicates the remote fault error. Possible values are
Error-Offline
(1000Base-X only) ,
Error-Link Fault
(1000Base-X only),
and
Error-Auto-Negotiation error
.
Speed
: Indicates the negotiated speed. Possible values are 10, 100,
and 1000.