SONET Tabs
170
FTB-8100 Series Transport Blazer
Section TX (SONET)
For
Manual
method:
³
Amount
:
Select the amount of manual error to be generated. Choices
are
1
through
50
. The default setting is
1
.
³
Send
button:
Press
Send
to manually generate error(s) according to
the
Error Type
and the
Amount of Errors
selected.
For
Rate
method:
³
Rate
:
Select the injection rate for the selected error. The rate must be
within the minimum and maximum values specified.
³
Continuous
:
Generates the selected error to its theoretical maximum
rate when the
Continuous
check box is selected. The
Continuous
check box is cleared by default.
³
On/Off
button: The On/Off button is used to activate/deactivate the
selected error at the rate specified or at its theoretical maximum rate
when the
Continuous
check box is selected. This setting is disabled
(Off) by default.
Alarm Generation
Allows
Continuous
alarm generation method.
³
Type
LOF
(Loss Of Frame): Generates non-valid framing bytes (A1 and A2).
SEF
(Severely Errored Framing): Generates four consecutive errored
framing patterns.
³
On/Off
button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default. Exceptionally
for continuous SEF alarm, the On/Off button turns Off once the SEF
alarm has been sent.
Summary of Contents for FTB-8100 Series
Page 1: ...User Guide FTB 8100 Series for FTB 200 SONET SDH Application...
Page 18: ......
Page 22: ......
Page 24: ......
Page 94: ......
Page 108: ......
Page 178: ......
Page 224: ......
Page 260: ......
Page 312: ......
Page 352: ......
Page 382: ......
Page 412: ......
Page 490: ......
Page 500: ......