Test Results
326
FTB-700G/800 Series
Alarms/Errors
S-OAM and MPLS-TP OAM
Alarms
Note:
The following alarms are available when the
CC Function
check box is
Loss Continuity
RX
: No CCM frames with same or lower MEG/MD Level were received
from the peer MEP within an interval equal to 3.5 times the configured
CCM transmission period. The alarm is cleared when at least 3 CCM
frames with same or lower MEG/MD Level from the peer MEP are
received within an interval equal to 3.5 times the configured CCM
transmission period.
Mismerge
RX
: A CCM frame was received from the peer MEP with same MEG/MD
Level but with incorrect MEG ID/MAID value or format. The MAID,
composed of a Domain ID and a Short MA Name strings, is incorrect if
one or both strings are not as expected. The alarm is cleared when no
CCM frames with same MEG/MD Level but with incorrect MEG ID/MAID
value or format are received within an interval equal to 3.5 times the
configured CCM transmission period.
Unexp MEG/MD Lvl
(Unexpected MEG/MD Level)
RX
: A CCM frames was received from the peer MEP with lower
MEG/MD Level. The alarm is cleared when no CCM frames with lower
MEG/MD Level are received within an interval equal to 3.5 times the
configured CCM transmission period.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...