![EXFO FTB-1 User Manual Download Page 329](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042329.webp)
Test Results
NetBlazer
317
Alarms/Errors
ODUx-TCM
Alarms
BDI
(Backward Defect Indication)
RX:
The BDI bit in the TCM overhead field Byte 3, bit 5 is “1” for at least
5 consecutive frames.
TX
: Generates a "1" in the BDI bit of the TCM overhead field (byte 3,
bit 5) continuously.
BIAE
(Backward Incoming Alignment Error)
RX:
The BEI/BIAE bits in the TCM overhead field Byte 3, bits 1 to 4 are
“1011” for at least 3 consecutive frames.
TX
: Generates "1011" in the BEI/BIAE bits of the TCM overhead (byte 3,
bits 1 to 4) continuously.
IAE
(Incoming Alignment Error)
RX:
The STAT information in the TCM is “010” for at least 3 consecutive
frames.
TX
: Generates "1" in the IAE bit of the TCM overhead (byte 3, bit 6)
continuously.
LTC
(Loss of Tandem Connection)
RX:
The STAT information in the TCM Byte 3, bits 6, 7, and 8 are “000”
for at least 3 consecutive frames.
TX
: Generates "000" in the STAT field of TCM overhead (byte 3, bits
6 to 8) continuously.
TIM
(Trace Identification Mismatch)
RX
: The SAPI and/or DAPI do not math the expected SAPI and/or DAPI.
This alarm is only available when the Enable TIM SAPI and/or DAPI
check boxes are selected from
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...