Test Setup - Test Configurator, Timer, and System
146
FTB-700G/800 Series
FTFL/PT
FTFL/PT
From the
Test
menu, tap
Setup
,
Test Configurator
, tap on the signal block,
and on the
FTFL/PT
tab.
FTFL
Allows the configuration of the Forward and Backward ODU Fault Type
Fault Location (FTFL) to be generated.
Fault Indication
and
Fault Indication Code
allow the selection of the
FTFL fault indicator message/code (byte 0 for forward, byte 128 for
backward) to be generated.
Note:
The
Fault Indication Code
field is automatically updated when the
Fault
Indication
is changed and vice versa.
Operator Identifier
allows editing the Operator Identifier to be
generated (bytes 1 to 9 for forward, bytes 129 to 137 for backward;
9 characters allowed). By default no Operator Identifier is defined.
Operator Specific
allows editing the Operator Specific to be
generated (bytes 10 to 127 for forward, bytes 138 to 255 for backward;
118 characters allowed). By default no Operator Specific is defined.
Fault Indication
Fault Indication Code (Hex)
No fault
00
(default)
Signal fail
01
Signal Degrade
02
Reserved
03
a
a.
Selecting
Reserved
will use the hexadecimal code
03
but, all codes from
03
to
FF
are reserved for future international standardization.
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...