![EXFO FTB-1 User Manual Download Page 139](http://html1.mh-extra.com/html/exfo/ftb-1/ftb-1_user-manual_2450042139.webp)
Test Setup - Test Configurator, Timer, and System
NetBlazer
127
Clock
For E1:
TERM
provides an input that terminates the E1 signal.
MON
provides high-input impedance and compensation for
resistive loss. This setting is useful for monitoring E1 signals at
monitor points, which are resistor-isolated.
BRIDGE
provides high-input impedance for bridging lines that are
already terminated. This setting is useful for bridging directly
across copper cable pairs.
Line Coding
allows the selection of the interface line coding.
For DS1:
AMI
and
B8ZS
(default).
For E1:
AMI
and
HDB3
(default).
Framing
: Allows the selection of the interface framing.
For DS1:
SF
,
SLC-96
, and
ESF
(default).
For E1:
PCM30
(default),
PCM30 CRC-4
,
PCM31
, and
PCM31 CRC-4
.
Frequency (MHz)
displays the frequency of the received signal rate.
Offset (ppm)
displays the positive or negative frequency offset
between the standard rate specification and the rate from the received
signal. The background color is used to indicate if the received clock
meets (green) or not (red) the standard rate specification.
Signal
Standard Rate specification
DS1
1544000 ± 8 bit/s (± 4.6 ppm)
E1
2048000 ± 10 bit/s (± 4.6 ppm)
2MHz
2048000 ± 10 bit/s (± 4.6 ppm)
Summary of Contents for FTB-1
Page 1: ...User Guide FTB 700G 800 Series NetBlazer for FTB 1 ETHERNET AND MULTISERVICE TESTER...
Page 12: ......
Page 20: ......
Page 22: ......
Page 52: ......
Page 59: ...Test Setup Test Applications NetBlazer 47 SONET SDH BERT For SDH BERT...
Page 64: ...Test Setup Test Applications 52 FTB 700G 800 Series SONET SDH DSn PDH BERT For SDH...
Page 84: ......
Page 98: ......
Page 298: ......
Page 574: ......
Page 652: ......
Page 674: ...0 5 1 5 48 5 0 176 W d y K y K D...