AC8-HD Series : Quick Start Guide
SIDE 1
Warning – Refer to Safety Precautions Booklet 035-00636R for all safety precautions prior to use.
User Guide 035-00677R download:
http://www.excelitas.com/Pages/Product/OmniCure-AC8-HD.aspx
WARNING:
Never look at operating LED! The light could severely damage the cornea and retina of the eye if the light is observed directly. Eye shielding
must be used at all times as well as clothing to protect exposed skin
Printed in Canada
Refer to user guide for more details.
035-00682R Rev. 0
SETUP / Unpack
•
Carefully unpack the unit and accessories from shipping carton.
•
When removing the LED Head, ensure that the optical window is not placed directly on
a surface to avoid any damage
.
1.1
System Requirements
In addition to the UV LED Head, you will require the following components:
•
Power supply
•
Power cable
Note:
You will also require a PLC controller or RS485 cable unless you are using an
existing controller. The PLC controller is used to discover the extensive functionality of
the UV LED Head, but integrators can access the full feature set through integrating
with the PLC or RS485 interface directly. Refer to
“Connecting the UV LED Head”
documentation in the User Guide
Connecting the Power Supply and PLC Controller
Note
: All connectors are via screw style fastener -- do not over tighten the
connector screws.
Note
: The following is a generic procedure, illustrated with the common
components described above. Refer to
“
Connecting the Power Supply and
PLC Controller”
documentation in the User Guide
Tip
: After securing the power cable to the power supply, it is recommended to
“tie-off” the female connector cable on to the mounting brackets or process
rigging as a form of strain relief.
1.
Make sure the power supply unit is turned off.
2.
Connect the AC power cord
to the power supply.
3.
Attach the male end of the
power cable to the power
supply unit, and connect the
female end of the power
cable to the UV LED Head
per
Figure 1 –
AC8300P-HD
shown.
Figure 1: UV LED Head Connection Ports
1.2
Powering Up and Powering Down
1.
Ensure that the system has been properly installed and the UV LED Head is securely
mounted with the optical lens in the desired orientation. Refer to
“Mounting the UV
Head”
documentation in the User Guide
2.
Verify that the power supply unit’s AC supply cord is connected to a properly grounded
AC outlet.
3.
If the power supply has a circuit breaker, switch it to the “ON” position.
4.
Turn the main power switch of the power supply to the “ON” position and check the fan
for airflow.
5.
The LED indicator on the UV LED Head will
flash
green during “boot-up” and change to a
steady
green indicating UV LED Head is ready for use. It is recommended to wait for 15
seconds from initial power-up before attempting to control the UV head. For more
information about the indicators. Refer to
“Using the LED Head”
in the User Guide
1.3
Using the LED Head
The peak wavelength of the UV LED Head is 365nm, 385nm, 395nm, or 405nm +/-
5nm, depending on model.
For all models, adjusting the UV LED Head intensity can be actuated by an external
controller via the PLC interface. Refer to
“Connecting UV LED Head”
documentation in the User Guide
Input voltage vs. desired intensity; 5V = 100% and 1V = 20%. A minimum voltage of
1V is required for light source operation.
Note:
The light source will maintain a 20% intensity when the input voltage is in the
range of 0.5V. If the input voltage is below this, the light source will turn off.
Ensure the UV LED Head indicator is illuminated to a steady green before applying
UV power to the head. The UV LED Head indicator will illuminate to a steady amber
indicating UV is on. When UV is off, the indicator will revert back to a steady green
indicating UV is off.
The UV LED Head is capable of responding to PLC control signals in less than 0.2
seconds. Understanding the LED Indicators