background image

XL8000 Series 

Door Closer Installation

Left hand fitting only, use reverse for right hand fitting.

Standard Door Installation (Pull Side) - Fig 1

Hinge knuckle

is visible

Door Frame

Door

2 - Latching Speed

Adjustment Valves

1 - Closing Speed

Door Closer Body

Armset Shoe

Frame Fix Installation (Push Side) - Fig 61

Hinge knuckle

is 

not

 visible

Door Frame

Door

Adjustment Valves

2 - Latching Speed

2 - Latching Speed

1 - Closing Speed

1 - Closing Speed

Door Closer Body

Armset Shoe

180 degree

door installation

120 degree

door installation

Step by Step Installation Guide

Use the appropriate template for your installation and place

the template on the door and frame. Pilot drill all fixing holes

as per the template.

1.

Position the door closer with the adjustment valves facing

the hinge side of the door. Secure the door closer using

the screws provided into the pre-drilled pilot positioning

holes.

2.

Attach the armset to the pivot on the door closer body and

secure using the washer screw.

3.

Tension the door closer arm and adjust the arm length

accordingly. Secure the arm set shoe to the door or frame

depending on installation, then tighten the arm set nut.

4.

Apply the dust cap to the unused pivot.

5.

Adjust the closing and latching speeds as required -

refer to adjustment instructions.

NB after the first month of operation the closing and latching

speed valves may require minor adjustment.

Standard Door Installation - View from above

Pull Side - Fig 1

Washer Screw

Dust Cap

Armset Pivot Screw

Hinge Knuckle

Adjustment Valves

Door Closer Body

Preload

Armset

Nut

Threaded

Arm (bolt)

Armset Shoe

Frame Fix Installation - View from below

Push Side - Fig 61

Hinge Knuckle

Adjustment Valves

Door Closer Body

Preload

Armset

Nut

Threaded

Arm (bolt)

Armset Shoe

Washer Screw

Armset Pivot Screw

Dust Cap

4  8  3  1  1  3 

EN1154:1996 / A1:2002 / AC:2006

EN1634-1:2008 FD30/FD60 Timber Doors

*Fig 1 Application Only

30/60

C

180 degree

door installation

120 degree

door installation

CAUTION

Adjusting valves more than 2 full turns 

anti-clockwise from factory settings will 

result in oil leakage damaging the door closer. 

Failure to comply with this will void the warranty.

Acceleration

Deceleration

Valve Adujustment Instruction Guide

Closing Speed:

 Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed. 

Latching Speed: 

Adjust valve by quarter turns 

anti-clockwise to increase speed or clockwise to 

reduce speed.