background image

AL-1855-EDPB

Feature Programming

:

Turn the ignition key “on, then “off”

1. 

Within 7 seconds of step 1, press the valet switch 5 times 

2. 

(user features) or 10 times (installer features). This 

siren/horn will sound.

Press the valet switch the number of times equal to the 

3. 

feature number you wish to access.

Press the controller/transmitter button that corresponds to 

4. 

the desired setting.

To change additional features, repeat steps 3-4.

5. 

To exit programming, turn the ignition key “on”, then “off” 

6. 

or the system will exit automatically if there is a 10 sec-

ond delay between any steps.

Tach Learning Procedure

:

Turn the ignition key “on”

1. 

Within 10 seconds of step 1, press the brake pedal 5 

2. 

times. The siren/horn will chirp 5 times.

Start the engine with the key. When tach is successfully 

3. 

learned, the status light will turn on solid.

If you need to relearn a later tach signal due to cold start/

4. 

high idle, you can press the valet switch once to learn 

the current tach signal. The status light will turn off and 

back on to indicate it has relearned.

Programming Controllers/Transmitters

:

Be sure to have all controllers/transmitters present and be 

1. 

sure the system is in a disarmed/unlocked state.

Turn the ignition key “on”.

2. 

Within 7 seconds of step 1, press the valet switch 5 times. 

3. 

The siren/horn will sound.

Press LOCK on one transmitter/controller until you hear a 

4. 

single chirp.

Repeat step 4 for each transmitter/controller to be pro-

5. 

grammed.

To exit programming, turn the ignition key “off” or the sys-

6. 

tem will exit automatically if there is a 10 second delay 

between any steps.

Programmable Features Matrix

DELUXE 2-WAY ALARM & REMOTE START SYSTEM

The 2-Way Controller 

Part number: 157-07

Battery: Rechargeable

Frequency: 900MHz

1

2

3

1

2

4

The 1-Way Transmitter 

Part number: 1410-07

Battery: 1 x CR2032

Frequency: 900MHz

LOCK button

1. 

UNLOCK button

2. 

TRUNK button

3. 

3

4

START button

4. 

PROGRAMMING button

5. 

Technology

5

User Feature Programming: Ignition on, off, press valet 5 times

# Feature

Lock Button

Unlock button

Trunk button 

”START” button

1   Secure Code

1, 0 (default)

2   Last Door Arming

Off

On w/o lock

On w/ Lock

3   Automatic Rearming

Off

On w/o lock

On w/ Lock

Enhanced Rearm

4   Starter Interrupt Functions

Alarm

Anti-Grind Only

Alarm+Anti-Grind

Automatic

5   Ignition Override

On

Off

6   Ignition Lock/Unlock

Off

Lock w/ IGN ON Unlock w/ IGN Off

Lock + Unlock w/ 

IGN On/Off

7   Open Door Bypass For Ign. Locks

On

Off

8   Confirmation Chirps

On

Except Valet 

mode

On Demand

Off

9  Chirp Volume

Low

Med Low

Med Loud

Loud

10  Alarm Cycle

30 sec

60

90

120

11  Flashing Lights Confirmation

On w/  

RS Steady

On  w/  Disarm  + 

RS Flashing

Steady During RS

Flashing  During 

RS

12  Disarm Upon Trunk Release

On

Off

13  Arming Delay

3 sec

15

30

45

14  Alarm Functions Bypass

On

Off

15  Anti-carjack

Ignition Only

Door Only

Ig Door

Off

16  Open Door Warning Upon Arm

On

Off

17  Remote Start Activation

Start / Pulse x 2 Start / Pulse x 1 Lock+Unlock

18  Remote Start Run Time

5 min

10 min

15 min

 20 min

Installer Feature Programming: Ignition on, off, press valet 10 times
1  Doorlock pulse

0.8 sec

3 sec

Double unlock

Total closure

2  Light Relay Functions

Dome light

Lock

Ignition

Acc

3  Horn Relay Functions

Horn

Unlock

Trunk Release

Pulse after Start

4  Turbo Timer

Off

1 min

2 min

3 min

5  Manual Transmission

On

Off

6  Engine detection

Tachless Hi

Tachless Lo

Tach Wire

Datatach

Crank Only (press Lock + Unlock)

7  Crank Time

0.7 sec

1 sec

1.5 sec

2.25 sec

8  Pink/White Ignition Wire Function

Ignition

Accessory

Start

9  Arm/Disarm/Additional Ch.

Arm/Disarm

Arm/Ch 5

Ch4/Disarm

Ch 4/Ch 5

10  Gas or Diesel Engine

Gas

Diesel  

(15 sec. Delay)

Diesel  

(20 sec. Delay)

Diesel  

(30 sec. delay)

11  Remote Start Lock control

Off

Lock after start

Unlock before start

Both

12  Low Temp Crank Extender

0ms

200ms

300ms

400ms

13  Data Port Protocol

D2D (Trilogix)

ADS (iData)

14  Lock on prewarn

On

Off

15  Blue Satellite Port Blue Wire Function

Status

Pulse Before 

Start

Pulse After Start 

Below Freezing

Pulse After 

Engine Off

16  Low Current/Motorcycle Mode

On

Off

Transmitter/Controller Operations

:

LOCK/ARM

: Press and release “lock” once

UNLOCK/DISARM

: Press and release “unlock” once

TRUNK RELEASE/2ND CH

: Press “trunk” for 3 seconds

REMOTE START

: Press “start” twice in 5 seconds

   

(see user feature #17 for options) 

REMOTE VALET

: Press “start” within 5 seconds of pressing 

“unlock” 

LOW BATTERY\LOW TEMP AUTO STARTING

: Press “start” 

within  5 seconds of pressing “lock” 

PANIC

: Press “lock” or “unlock” for 3 seconds

SILENT ARM/DISARM

: Press “trunk” twice in 5 seconds

SENSOR BYPASS

: Press “trunk” within 5 seconds of arming 

Reviews: