![Exar XRT86VL38 Manual Download Page 349](http://html1.mh-extra.com/html/exar/xrt86vl38/xrt86vl38_manual_2448858349.webp)
xr
PRELIMINARY
XRT86VL38
REV. P1.0.6
OCTAL T1/E1/J1 FRAMER/LIU COMBO
338
6.2.3
Configure the DS1 Receive Overhead Output Interface module as destination of the
Signaling Framing (Fs) bits in N or SLC®96 framing format mode
The Fs bits in SLC®96 and N framing format mode can be extracted to:
•
DS1 Receive Overhead Output Interface Block
•
DS1 Receive HDLC Controller
•
DS1 Receive Serial Output Interface.
The Receive Data Link Source Select bits of the Receive Data Link Select Register (RDLSR) controls the
destination of Fs bits in N or SLC®96 framing format mode. The table below shows configuration of the
Receive Data Link Source Select bits of the Receive Data Link Select Register (RDLSR).
If the Receive Data Link Source Select bits of the Receive Data Link Select Register are set to 10, the Receive
Overhead Output Interface Block outputs Fs bits extracted from the incoming T1 data stream.
F
IGURE
45. DS1 R
ECEIVE
O
VERHEAD
O
UTPUT
I
NTERFACE
MODULE
IN
ESF
FRAMING
FORMAT
MODE
RECEIVE DATA LINK SELECT REGISTER (TDLSR) (ADDRESS = 0XN10AH)
B
IT
N
UMBER
B
IT
N
AME
B
IT
T
YPE
B
IT
D
ESCRIPTION
1-0
Receive Data Link
Source Select
R/W
00 - The extracted Facility Data Link bits are stored in either the LAPD con-
troller or the SLC®96 buffer. At the same time, the extracted Facility Data
Link bits are outputted from the framer through the Receive Serial Data
Output Interface via the RxSer_n pins.
01 - The extracted Facility Data Link bits are outputted from the framer
through the Receive Serial Data Output Interface via the RxSer_n pins.
10 - The extracted Facility Data Link bits are outputted from the framer
through the Receive Overhead Output Interface via the RxOH_n pins. At
the same time, the extracted Facility Data Link bits are outputted from the
framer through the Receive Serial Data Output Interface via the RxSer_n
pins.
11 - The Facility Data Link bits are forced to one by the framer.
RxOhClk
(2KHz,even)
RxOh
(2KHz,even)
RxOh
(4KHz)
RxOhClk
(2KHz,odd)
RxOh
(2KHz,odd)
Frame #
RxSync
RxOhClk
(4KHz)
1
2
6
3
4
5
7
8
9
10
11
12
13
14
15
16
17
18
19