The Temperature alarm monitors the internal temperature of the unit based on specific points inside
the radio chassis. It is normal for the internal temperature to be above the ambient temperature, so the
temperature reading may be higher than the highest specified ambient temperature. When the internal
electronics reach a point that is higher than the normal temperature rise at the highest ambient
temperature, the temperature alarm turns yellow. Power down the radio as soon as possible, and
investigate the cause of the temperature rise before the radio is put back into service. In almost all
cases, a temperature alarm is due to an external cause.
Additional alarm entries display for certain configurations, as listed in Table 6.
ATPC
Indicates Automatic Transmit Power Control status:
• Green Solid = ATPC is enabled, but not active.
• Yellow Solid = ATPC is active.
• Red Solid = ATPC timers have reached limit (and link has not recovered to target RSL).
• Grey = ATPC is disabled.
PA Protection
Indicates the status of power amplifier protection:
• Green Solid = PA is OK; not in a maintenance state.
• Yellow Solid = PA is in a maintenance state (force high or force low, as set on the
).
• Red Solid = PA has detected an issue.
Ethernet
• Green Solid = Alarm enabled and Ethernet link present
• Red = Alarm enabled and Ethernet link not present
• Grey = Alarm disabled
DS3 Input
• Green = Enabled and connection present (clocking confirmed)
• Red = Enabled and no connection present
• Yellow = Disabled and connection present
• Grey = Disabled or unavailable due to configuration
T1/E1 Input
• Green = Enabled and connection present (clocking confirmed)
• Yellow = Disabled and connection present
• Red = Enabled and no connection present
• Grey = Disabled or unavailable due to configuration
Temperature
• Green Solid = Normal temperature range
• Yellow Solid = Exceeding normal temperature range
Internal Fan
Indicates the internal fan status. There are 3 fans for redundancy.
• Green = Fan OK
• Red = Fan in alarm
External Inputs (1 and 2) Indicates the status of the external alarm inputs from the ALARMS connector, in accordance
with the open/closed logic defined on the
Link Security
• Green = Security keys match
• Red = Security keys do not match
• Grey = Link is down
Table 5 Alarm status indicators (Continued)
Label
Status