Exalt Installation and Management Guide
EX-i Series FDD Digital Microwave Radios
12
202675-005
2011-08-30
Record Keeping
After installation, record the following items for ongoing maintenance and future troubleshooting.
Keep a record for each end of the radio link and store a copy of these records at the radio location, at
the opposite end radio location, and a central record storage location.
•
GPS coordinates for antenna locations at each site
•
Antenna heights above ground level (AGL), as mounted
•
Antenna model numbers, serial numbers, and specifications
•
Antenna polarization as mounted
•
Length/type of primary transmission lines at each site
•
Model number and serial number of RF lightning arrestors (for systems using coaxial transmission
line only)
•
Length/type of secondary transmission line(s)
•
Transmitter output power setting as installed at each site
•
RSL as measured after antenna alignment at each site
•
Designed RSL per original design at each site
•
RSL reading with far-end power off (from each end)
•
plot with far end off at each site
•
Radio’s network management IP address at each site
•
Radio’s network management gateway address at each site
•
Radio’s operating frequency, bandwidth setting, and mode of operation
•
Optionally purchased extended warranty and/or emergency service contract details
In addition, certain information may be desired for central record-keeping only:
•
Link security codes and log in passwords (stored in a secure place)
•
Photographs of complete installation
•
End-user sign-off/acceptance documentation (if any)
•
Photo of product identification label (part number, serial number, MAC address information)
•
Electronic copy of radio’s configuration file
•
Electronic copy of radio’s installed software
Summary of Contents for EX i GigE Series