Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
78
201872-003
2015-10-23
Interfaces
RF (x2 for EX-4.5r-c GigE and EX
-
5r-c GigE)
TDM (x2, 2 interfaces each)
Ethernet
(
x2
)
Sync-Out
Sync-I n
Power — Power Injector
Integrated Antenna
Connector
N-type female
Impedance
50 Ohms
Connector
RJ-45 (RJ48C), female
T1 Impedance
100 Ohms, balanced
T1 Line Codes
AMI, B8ZS, selectable
T1 LBO Settings (in ft.)
0-133, 133-266, 266-399, 399-533, 533-655
T1 Clocking Speed
1.544 Mbps
T1 Compliance
ANSI T1.102-1987; ITU-T; G.823; GR-49T-CORE
E1 Impedance
120 Ohms, balanced
E1 Line Codes
HDB3
E1 Clocking Speed
2.048 Mbps
E1 Compliance
CEPT-1; G.703; ITU-T-G703
Connectors
RJ-45, female, auto-MDIX
Interface Speed
10, 100, or 1000 Mbps
Duplex
Half, full, auto, selectable
Compliance
802.3
Connector
RJ-45, female
Signal
0.5 to 5µsec pulse, based on frame size setting
Connector
RJ-45, female
Signal
From Sync-out or 1pps (GPS)
Connector
6-pin barrier strip
Input Voltage
48VDC
Consumption
<65 W (1.35A)
Gain
24dBi (midband, EX-5r GigE)
21dBi (midband, EX-4.5r GigE)
3dB Beamwidth
9 degrees (EX-5r GigE)
10 degrees (EX-4.5r GigE)
Polarization
Switch-selectable Vertical or Horizontal or Cross