QUICK START GUIDE

Pool

ADVANCED PHOTOMETER SYSTEM

DIGITAL ACCURACY FOR BETTER POOL CARE

Summary of Contents for Pool EZ

Page 1: ...1 Sensafe com QUICK START GUIDE Pool ADVANCED PHOTOMETER SYSTEM DIGITAL ACCURACY FOR BETTER POOL CARE...

Page 2: ...inity Calcium Hardness Phosphate Chloride and Copper WHAT YOU WILL NEED TO GET STARTED Four 4 AAA batteries 4 Phillips head screwdriver Note This system has been calibrated for use with only our eXact...

Page 3: ...meter on and creates a baseline for your water testing CELL COVER Covers the cell for mixing and bright light situations Protected against the effects of immersion in water to depth between 15cm and 1...

Page 4: ...R Press and the LCD Display reads 0PPM indicating the meter is ready for testing 4 FILL DIP READ In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times...

Page 5: ...initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer display...

Page 6: ...Pool eXact EZ 3 SELECT TEST Press and re press the button until the display shows PH2 ZERO METER Press and the LCD Display reads 0 0PH indicating the meter is ready for testing 4 In bright light situ...

Page 7: ...result is automatically stored in the PH2 menu After testing is complete rinse the sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP th...

Page 8: ...ows CL3 ZERO METER Press and the LCD Display reads 0 00PPM indicating the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP Use the included cleaning b...

Page 9: ...nstant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Free Chlorine for result as Bromine multply value by 2...

Page 10: ...dure is a continuation from Free Chlorine Test Method on previous pages DO NOT DISCARD SAMPLE FROM FREE CHLORINE TEST REMOVE STRIP Remove one eXact Strip Micro CL DPD 3 Combined Chlorine and set in a...

Page 11: ...lorine reaction at all levels Chlorine Dioxide ClO2 Color similar to free chlorine reaction at all levels Copper Cu 2 Color development is reduced above 10 ppm mg L Iodine I2 Color similar to free chl...

Page 12: ...g the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP Clean CELL with 0 1N HCl Distilled Vinegar 5 or Muriatic Acid before filling the meter with the...

Page 13: ...IP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip The display will a...

Page 14: ...R Press and the LCD Display reads 0PPM indicating the meter is ready for testing 4 FILL DIP READ In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times...

Page 15: ...s CaCO3 This result is automatically stored in the CA5 menu After testing is complete rinse the sample cell immediately 7 FILL DIP READ DIP STRIP AND PRESS READ Press to initiate a 20 second countdown...

Page 16: ...ZERO METER Place cell cover on sample cell before zeroing Press and the LCD Display reads 0PPM indicating the meter is ready for testing 4 FILL DIP READ FILL CELL Rinse the cell 3 times with the wate...

Page 17: ...READ result displayed as Cyanuric Acid This result is automatically stored in the CY6 menu After testing is complete rinse the sample cell immediately 7 FILL DIP READ CAP PRESS READ Place the cell cov...

Page 18: ...ERO METER Press and the LCD Display reads 0 00PPM indicating the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times wit...

Page 19: ...the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip The display will aut...

Page 20: ...the 2 0mL line very precisely plunger ring should line up at the 2 0mL line and little or no air bubble should be present 3 Add the syringe content 2 0mL salt water sample to a clean 50mL graduated c...

Page 21: ...and the LCD Display reads 0 00PPM indicating the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times with the water sam...

Page 22: ...ubmerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip 6 READ RESULTS READ result displayed as C...

Page 23: ...e Test immediately after filling the cell with the water sample To obtain optimal accuracy when testing outdoors sunlight use the cell cover when zeroing and reading the sample Due to the strip slitti...

Page 24: ...technical information and how to videos For additional technical support call 803 329 9712 Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 800 861 9712 or 803 329 9712 its sensafe...

Page 25: ...email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS Damage caused by improper packing of the photometer for return shipment to I...

Page 26: ...hlorine and the eXact Strip Micro CL DPD 3 for Combined Chlorine and the eXact Strip Micro CL DPD 4 for Total Chlorine meet your reportable testing requirements because the eXact Strip Micro strips de...

Page 27: ...27 Sensafe com NOTES...

Page 28: ...rial Test Systems Inc Rock Hill SC USA EXACT MICRO TESTS REAGENTS PARAMETER TEST 1 PART RANGE ppm BEST ACCURACY OF TESTS Alkalinity Total 486641 10 200 10 100 Alkalinity Total Range Extender 2 486665...

Reviews: