33
6. Setup and operation
Warning: Setup, Handling, Service must be done by a qualified person!
Qualified persons are specialists like electricians or persons with similar or
higher qualification.
6.1 Notes on installation and operation
The V1000E was carefully inspected and subjected to a functional check before delivery. The
high-quality packaging is designed to prevent damage in transit. Even with the most careful
handling, damage cannot be completely avoided. Possible transport damage particularly affects
the UVC tubes made of quartz glass. Examine the UVC tubes and lamp sockets before
installation. Check that the cables are not damaged. Check the completeness of the delivery
using the parts list.
Attention: The device shall only be installed with an intact cable. Check cables
and connectors before installation
The V1000E weights around 29kg. Any handling of the devices must be carried out
by at least two people. Additional people may have to be included in the installation
process.
The installation location must be chosen so that people present are not permanently closer than
0.5 m to the device.
Attention: People who are permanently in the proximity of the device should
keep a distance of 0.5m to the device.
The V1000E as well as the light traps must be checked for intactness before installation and
regularly during operation in order to detect increased emittance of UVC light. The risk from
possible emitting UVC radiation must be checked and documented using an appropriate
measuring device (see chapter 4.2 UVC Safe handheld measurement device).
Attention: Check the V1000E for intactness before assembly and regularly
during operation. The risk from possible UVC radiation must be checked and
documented using a UVC measuring device.