Design and function
PC interface
52
099-000125-EW501
29.9.2022
5.4.6.2 Responsiveness
This function controls the responsiveness of the welding current during the main current phase. The user
can choose between linear and logarithmic responsiveness. The logarithmic setting is particularly suitable
for welding with low current, e.g., for thin panels as the logarithmic responsiveness enables better control
of the welding current.
The responsiveness function can be switched in the machine configuration menu between the parame-
ters for linear and logarithmic responsiveness (factory set)
> see 5.8 chapter
.
Figure 5-36
5.5 PC interface
Welding parameter software
Set all welding parameters on the PC and simply transfer to one or more welding machines (accessory,
set consisting of software, interface, connection leads)
• Data exchange between power source and PC
• Welding task administration (JOBs)
• Online-data exchange
• Default settings for welding data monitoring
• Update function for new welding parameters
5.5.1 Connection
Equipment damage or faults may occur if the PC is connected incorrectly!
Not using the SECINT X10USB interface results in equipment damage or faults in signal trans-
mission. The PC may be destroyed due to high frequency ignition pulses.
• Interface SECINT X10USB must be connected between the PC and the welding machine!
• The connection must only be made using the cables supplied (do not use any additional ex-
tension cables)!
Figure 5-37
Item Symbol Description
0
1
Connection socket (9-pole) - D-Sub
PC interface
2
Connection cable, 9-pole, serial
3
SECINT X10 USB