Appendix
Parameter overview – setting ranges
099-00T405-EW501
02.07.2020
51
7
Appendix
7.1 Parameter overview – setting ranges
7.1.1 TIG welding
Name
Display
Setting range
Code
Standard
Unit
m
in.
m
ax.
Main current AMP, depending on power source
-
A
-
-
-
Gas pre-flow time
0,5
s
0
-
20
Ignition current, percentage of AMP
20
%
1
- 200
Ignition current, absolute, depending on power source
-
A
-
-
-
Start time
0,01 s
0,01 - 20,0
Up-slope time
1,0
s
0,0 - 20,0
Pulse current
140 %
1
200
Pulse time
[1]
0,01 s
0,00 - 20,0
Slope time (time from main current AMP to secondary current
AMP%)
0,00 s
0,00 - 20,0
Secondary current, percentage of AMP
50
%
1
200
Secondary current, absolute, depending on power source
-
A
-
-
Pulse pause time
[1]
0,01 s
0,00 - 20,0
Slope time (time from main current AMP to secondary current
AMP%)
0,00 s
0,00 - 20,0
Down-slope time
1,0
s
0,0 - 20,0
End current, percentage of AMP
20
%
1
- 200
End current, absolute, depending on power source
-
A
-
-
-
End current time
0,01 s
0,01 - 20,0
Gas post-flow time
8
s
0,0 - 40,0
Electrode diameter, metric
2,4 mm 1,0 - 4,0
Electrode diameter, imperial
92 mil
40
- 160
spotArc time
2
s
0,01 - 20,0
spotmatic time (
>
)
200 ms
5
- 999
spotmatic time (
>
)
2
s
0,01 - 20,0
AC commutation optimisation
[1], [2], [3]
250
5
- 375
AC balance (JOB 0)
[1], [2]
%
-30 - +30
AC balance (JOB 1-100)
[2]
65
%
40
-
90
Current jump
[3]
1
A
1
-
20
Current jump
[4]
1
A
1
-
10
Re-igniting after arc interruption
[3]
5
s
0,1
5
AC frequency
[4]
-
Hz
50
- 200
AC frequency (JOB 0)
[1], [2], [3]
-
Hz
30
- 300
AC frequency (JOB 1-100)
[1], [2]
50
Hz
30
- 300
Pulse balance
50
%
1
-
99
Pulse frequency (mean value pulsing, DC voltage)
2,8 Hz
0,2 - 2000
Pulse frequency (mean value pulsing, DC voltage)
[1]
2,8 Hz
0,2 -
5
Pulse frequency (metallurgical pulsing)
[3]
50
Hz
50
- 15000
Pulse frequency (metallurgical pulsing)
[4]
50
Hz
5
- 15000
activArc, depending on main current
0
- 100