Machine control – Operating elements
Overview of control sections
099-00T405-EW501
02.07.2020
11
4.1.1 Control section A
Figure 4-2
Item Symbol Description
0
1
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 4.2 chapter
2
Push-button gas test / rinse hose package
> see 5.1.1 chapter
3
Operating mode
> see 5.1.4 chapter
/ power-saving mode push-
button
> see 5.3 chapter
--------- Latched
------- Non-latched
------- spotArc spot welding procedure – signal light turns green
------- spotmatic spot welding procedure –signal light turns red
--------- Press button for long interval to put machine into power-saving mode.
Activate one of the operating elements to reactivate.
4
Pulsed welding push-button
TIG ------- pulsed welding
> see 5.1.5 chapter
MMA ----- pulsed welding
> see 5.2.5 chapter
5
Welding procedure push-button
---------- TIG welding
------ MMA welding (signal light turns green)
------ Arcforce setting (signal light turns red)
6
Display switching push-button
kW ------- Welding power display
V ---------- Welding voltage display
7
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 4.2 chapter
8
TIG ignition type signal light
Signal light on: Lift arc ignition active/HF start off. You can switch the ignition type in the
Expert menu (TIG)
> see 5.1.10 chapter
.
9
Character function signal light
Indicates that it is possible to weld in an environment with major electric hazards, such
as in boilers. Service must be informed if this signal light is not on.
10
Coolant fault signal light
Signals pressure loss or low coolant level in the coolant circuit.