Rectifying faults
Dynamic power adjustment
099-00T406-EW501
13.07.2017
45
5.2
Dynamic power adjustment
This requires use of the appropriate mains fuse.
Observe mains fuse specification!
This function enables aligning the machine to the mains connection fusing to avoid continuous tripping of
the mains fuse. The maximum power input of the machine is limited by an exemplary value for the exis-
ting mains fuse (several levels available).
You can predefine this value in the machine configuration menu
> see 4.6 chapter
using parameter
.
The selected value will be shown on the machine display
for two seconds after the machine has be-
en switched on.
The function automatically adjusts the welding power to an uncritical level for the mains fuse.
When using a 20-A mains fuse, a suitable mains plug has to be installed by a qualified electrician.
5.3
Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
RESET
l
0
+
+
Figure 5-1
Display
Setting/selection
Input confirmation
User entries are applied, release button(s).
5.4
Display machine control software version
The query of the software versions only serves to inform the authorised service staff. It is available in the
machine configuration menu
> see 4.6 chapter
.