Configuration data overview
Tetrix / forceTig system
099-000769-EW501
29.06.2015
47
Parameter
Setting
Meaning
Available
from SW
Activate control voltage
X6/8
No
Yes
No analysis of the analog
channel.
The analog channel.is
analysed based on the control
voltage selection.
0.0.5.0
Control voltage X6/8
parameter
Hot wire
Oscillation
Filler wire down-slope value
The control voltage controls
the hot wire current.
The control voltage controls
the oscillation frequency for
tigSpeed.
The control voltage controls
the
down-slope value of the
filler wire for thermal pulsing
mode.
0.0.5.0
Control voltage scaling Value
Defines the input scaling for
the hot wire current.
0.0.5.0
Filler wire control
signal scaling
10.0 m/min
24.0 m/min
Defines the scaling when
selecting the filler wire
resolution in the JOB.
0.0.5.0
Factory reset
Off
Configuration
The setting has no function.
The machine will be reset to
the factory settings, effective
on the next start of the
machine.
0.0.5.0