Overview of plug (jumper) configurations
Scope of diagnostics
099-000769-EW501
29.06.2015
37
JP no.: Function/meaning
Assignment
12
JOB selection default setting -
JOBs are selected via external
machines
(e.g. JOB manager) and the RINT X12
does not
analyse the signals for the JOB numbers.
You can
override this selection with the
external signal X9/11.
(factory setting)
X
JOBs are selected via the RINT X12, the signals for
the JOB number are assumed from the RINT X12. No
external X9/11 signal
required.
13
Advanced JOB mode
-
No advanced JOB mode.
X
Advanced JOB mode is enabled.
14
Special signals active
-
The relays are used for the monitoring function
X
The relays are used for process signals
15
Reserved
16
Selecting the welding system -
Tetrix / forceTig welding system expected
X
Phoenix / alpha Q welding system expected
17
Diagnostics/programming
interface switching
-
Firmware programming possible via X13
X
Diagnostics possible via X12
(1)
Depending on the configuration, the latched operating mode can be activated using the EWM Config
Tool.
Given below is a list of all relevant control signal assignments of the RINT X12 to the cascade control.