Overview of plug (jumper) configurations
Scope of diagnostics
36
099-000769-EW501
29.06.2015
7
Overview of plug (jumper) configurations
The following table gives an overview of the RINT X12 jumper assignment:
JP no.: Function/meaning
Assignment
1 & 2
Main control signal
standardisation
Phoenix / alpha Q
Tetrix / forceTig
JP1
JP2
X
X
0 to 24 m/min (factory setting)
X
-
0 to 30 m/min
-
X
0 to 10 m/min
-
-
0 to 20 m/min
JP1
JP2
X
X
0 to 1000 A
X
-
0 to 500 A
-
X
0 to 100 A
-
-
0 to system nominal current
(factory setting)
3
Selecting the JOB counting
method
-
0..510 (counting method 1..511)
X
1..510 (counting method 1..510)
4 & 5
Selecting the input logic
1–2
Positive input logic (factory setting)
2–3
Negative input logic
6
Start enabling default setting -
RINT X12 only reacts to a start signal if
external signal X10/3 is set
X
Start signal is always accepted, no
X10/3 signal
required
7
Control voltage active default
setting
-
No external control signals are accepted
except when overriding by means of signal
X10/4. (factory setting)
X
External control signals are always accepted,
no external X10/4 signal required.
8
Inching mode default setting -
Inching by means of a ramp function which can be
overridden by the external X10/9
signal (factory setting).
X
Inching is always performed at a constant speed, no
external X10/9 signal required.
9 & 10
Operating mode default
setting
Operating mode with latched
modes disabled
Operating mode with latched
modes enabled
JP9
JP10
(1)
-
-
Non-
latched
X
-
Non-
latched
-
X
Non-
latched
X
X
Special
non-latched
JP9
JP10
(1)
-
-
Non-
latched
X
-
Latched
-
X
X
Special latched
X
X
Special
non-latched
11
Pulse process default setting -
Standard welding is active. This signal can be
overridden by the external X5/5 signal. (factory
setting)
X
Pulse welding is active, no external X5/5 signal
required.