Design and function
Permanently configurable standard signals
099-000769-EW501
29.06.2015
15
5.3.4
Operating modes
With jumpers JP9 and JP10 the individual operating modes can be set as a fixed value.
JP9/X5/3
JP10/X5/4
Operating mode with
latched modes
disabled
Operating mode with
latched modes
enabled
-
-
Non-latched
Non-latched
-
X
Non-latched
Latched
X
-
Non-latched
Special latched
X
X
Special non-latched
Special non-latched
Alternatively, the operating mode can also be actuated via the external signals X5/3 and X5/4.
The factory settings are such that JP9 and JP10 are not set.
5.3.5
Pulse process
With the JP11 jumper, a pulse process can be pre-defined on the RINT X12.
Alternatively, the signal can also be actuated by an external signal:
JP11
Operating mode
-
Standard welding is active. This signal can be overridden by
the external X5/5 signal. (Factory setting)
X
Pulse welding is active; an external X5/5 signal is not
necessary.
In Tetrix / forceTig systems, thermal pulsing is controlled with this signal.
5.3.6
JOB selection
The RINT X12 can be permanently configured for the selection of JOBs,
or the signal can be activated by an external signal:
JP12
Operating mode
-
JOBs are selected via external machines (e.g. JOB manager)
and the RINT X12 does not analyse the signals for the JOB
numbers. You can override this selection with the external
signal X9/11. (factory setting)
X
JOBs are selected via the RINT X12, the signals for the JOB
number are assumed from the RINT X12. No external X9/11
signal is required.