Design and function
Basic configuration using plug-in jumpers
099-000769-EW501
29.06.2015
13
5.2.3
Main control signal standardisation
Jumpers 1 and 2 can be configured to modify the main control signal. In this process, the actuation range
for the WF value (MIG/MAG) or the welding current setpoint value (TIG) is modified according to the
configuration for control signal operation.
MIG/MAG processes (Phoenix / alpha Q):
JP 1
JP 2
Input logic
X
X
0 to 24 m/min (factory setting)
X
-
0 to 30 m/min
-
X
0 to 10 m/min
-
-
0 to 20 m/min
TIG processes (Tetrix / forceTig):
JP 1
JP 2
Input logic
X
X
0 to 1000 A/min
X
-
0 to 500 A
-
X
0 to 100 A
-
-
0 to nominal system current
(factory setting)
(1)
(1)
The nominal system current comes from the type designation and is automatically detected by the
RINT X12 when the system is switched on.
5.2.4
Selecting the JOB counting method
The counting method for welding characteristics (JOBs) usually is 1 to 255. The values are stored in an 8
bit field so that, in general, 256 JOBs can be selected. System displays are compatible with the JOB
counting method 1 to 255. The possibility to select all 256 JOBs at the power source can be configured
with jumper 3. In this case, the counting method starts with the value 0 for JOB 1.
JP 3
Signal
Counting method/system
display
-
0…255
1…256/511
(2)
X
1…255
(1)
1…255/510
(2)
(factory setting)
(1)
Signal activation 0 causes no change
2)
Must be supported by the welding system (Multimatrix machine).