Design and function
Transport and installation
22
099-002058-EW501
26.11.2020
5.1.7 Mains connection
DANGER
Hazards caused by improper mains connection!
An improper mains connection can cause injuries or damage property!
• The connection (mains plug or cable), the repair or voltage adjustment of the device must
be carried out by a qualified electrician in accordance with the respective local laws or nati-
onal regulations!
• The mains voltage indicated on the rating plate must match the supply voltage.
• Only operate machine using a socket that has correctly fitted protective earth.
• Mains plug, socket and lead must be checked by a qualified electrician on a regular basis!
• When operating the generator, always ensure it is earthed as stipulated in the operating in-
structions. The network created must be suitable for operating machines according to pro-
tection class I.
5.1.7.1 Mains configuration
The machine may only be connected to a one-phase system with two conductors and an earthed
neutral conductor.
Figure 5-5
Legend
Item
Designation
Colour code
L
Outer conductor
brown
N
Neutral conductor
blue
PE
Protective conductor
green-yellow
• Insert mains plug of the switched-off machine into the appropriate socket.