Design and function
MIG/MAG welding
099-002061-EW501
05.05.2020
33
5.3.3 MIG/MAG welding with constant voltage characteristics (CV)
Default characteristics "CV constant voltage" for nearly all MIG/MAG processes
5.3.3.1 Welding task selection
?
Figure 5-24
5.3.3.2 Expert menu
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
The setting ranges for the parameter values are summarised in the Parameter overview section.
ENTER
EXIT
Figure 5-25
Display
Setting/selection
Dynamic correction
• Increase value > harder arc
• Decrease value > softer arc
5.3.4 MIG/MAG welding with constant current characteristics (CC)
Used for special wires (flux cored wires), which, according to the manufacturer, are to be welded using
"CC constant current"
5.3.4.1 Welding task selection
?
Figure 5-26