Design and function
Machine configuration menu
88
099-005504-EW501
20.11.2015
5.18 Machine configuration menu
5.18.1 Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off the machine at the main switch.
• Press and hold the "welding parameters" or "choke effect" (drive 4X LP) push-button and
switch the machine on again at the same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "welding parameter setting" rotary knob.
• Set or change parameters by turning the "arc length correction/select welding program" rotary
knob.
EXIT (Exit the menu)
• Press the "parameter selection right" push-button (switch machine off and on again).
ENTER
EXIT
NAVIGATION
l
0
l
0
Prog
VOLT
kW
+
M3.7x-B, D
(LP
)
+
M3
.7x
-A,
C
(HP
)
Figure 5-45
Display
Setting/selection
Lead resistance 1
Lead resistance for the first welding circuit 0
mΩ–60 mΩ (8 mΩ ex works).
Lead resistance 2
Lead resistance for the second welding circuit 0
mΩ–60 mΩ (8 mΩ ex works).
Only qualified service personnel may change the parameters!
Only qualified service personnel may change the parameters!
Time-based power-saving mode
• 5 min.–60 min. = Time to activation of power-saving mode in case of inactivity.
• off = inactivated
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!